Victron VDI-32 Galvanic Isolator (32 Amps)

Victron VDI-32 Galvanic Isolator (32 Amps) The Victron VDI-32 galvanic isolator consists of two internal diodes that are connected in anti-parallel fashion. When diodes are connected as such they allow current in both directions, but only above a threshold voltage of about 1.4 Vdc. The isolator is installed directly behind your boat's 230V connection. The forward voltage from the galvanic isolator is higher than the potential difference between metals, resulting in the voltage not being allow to conduct and as such, the galvanic isolator will prevent any electrolytic current. However, if there is a (higher) error voltage in the AC circuit, the diodes will allow current through and the residual-current device will break the circuit. The Victron VDI-32 galvanic isolation electrolysis blocker is rated for a maximum current of 32 amps. To meet the standard CE (ENISO 13297) the ground wire of the shore power installa..

(13)

523.74€ 518.50€ Ex Tax: 518.50€

Victron VDI-16 Galvanic Isolator (16 Amps)

Victron VDI-16 Galvanic Isolator (16 Amps) The Victron VDI-16 galvanic isolator consists of two internal diodes that are connected in anti-parallel fashion. When diodes are connected as such they allow current in both directions, but only above a threshold voltage of about 1.4 Vdc. The isolator is installed directly behind your boat's 230V connection. The forward voltage from the galvanic isolator is higher than the potential difference between metals, resulting in the voltage not being allow to conduct and as such, the galvanic isolator will prevent any electrolytic current. However, if there is a (higher) error voltage in the AC circuit, the diodes will allow current through and the residual-current device will break the circuit. The Victron VDI-16 galvanic isolation electrolysis blocker is rated for a maximum current of 16 amps. To meet the standard CE (ENISO 13297) the ground wire of the shore power installa..

(11)

228.02€ 225.74€ Ex Tax: 225.74€

Index Marine IM2160 Galvanic Isolator (32 Amps)

Index Marine IM2160 Galvanic Isolator (32 Amps) This Index Marine galvanic isolation blocker eliminates the potential difference between boats and the shore, preventing galvanic action caused by the different metals used. The IM2160A32 galvanic isolator electrolysis blocker is rated for a maximum current of 32 amps. Unit Classification: 32A Shore Inlet Compatibility: Single: 30, 32A Dual: 15, 16, 30, 32A 120/240Vac: 120V / 240V AC AC Frequency: 50/60Hz Max. Continuous Current: 35A Max. Surge Current: 400A Operating Temperature Range: -55°C to 150°C Weight: 642g Installation Instructions 1 - Mounting the isolator: The IM2160 galvanic isolator unit should be mounted using the screws provided and located in a position that will not be subjected to excessive heat (e.g. close to the engine or exhaust system). It should also be positioned as close as possible to the shore power connector; the point at which the mains electricity supply enters the vess..

(6)

219.43€ 217.23€ Ex Tax: 217.23€

Index Marine IM2160 Galvanic Isolator (16 Amps)

Index Marine IM2160 Galvanic Isolator (16 Amps) This Index Marine galvanic isolation blocker eliminates the potential difference between boats and the shore, preventing galvanic action caused by the different metals used. The IM2160A16 galvanic isolator electrolysis blocker is rated for a maximum current of 16 amps. Unit Classification: 16A Shore Inlet Compatibility: Single: 15, 16A Dual: 15,16A 120/240Vac: 120/240V AC AC Frequency: 50/60Hz Max. Continuous Current: 35A Max. Surge Current: 400A Operating Temperature Range: -55°C to 150°C Weight: 592g Installation Instructions: 1 - Mounting the isolator: The IM2160 galvanic isolator unit should be mounted using the screws provided and located in a position that will not be subjected to excessive heat (e.g. close to the engine or exhaust system). It should also be positioned as close as possible to the shore power connector; the point at which the mains electricity supply enters the vessel. 2 - Dis..

(11)

175.54€ 173.79€ Ex Tax: 173.79€

Index Marine Electrical Status/Fault Indicator 2200

Index Marine Electrical Status/Fault Indicator 2200 The Index Marine 2200 electrical status/fault indicator utilises the galvanic isolator as a current flow sensor, detecting current flow and voltage drop across the device’s terminals. The galvanic isolation status indicator should be mounted in a prominent position on the boat so that crew and users are immediately alerted to electrical faults that could be hazardous to those on board the vessel, and/or cause an increase in galvanic corrosion. Passive Detection - The electrical fault indicator has no power consumption under normal conditions. It only receives power when there is current flowing through the galvanic isolator, and then it accurately indicates a fault in the vessel (or shore power) electrical system. The 2200 provides an LED light panel to monitor problems with the vessel earthing system and any AC or DC fault conditions. If there is a fault alert you should shut down electrics imm..

(8)